Leica Freeze Fracture System - Leica EM ACE900
  • Leica Freeze Fracture System - Leica EM ACE900
Leica Freeze Fracture System - Leica EM ACE900

Leica Freeze Fracture System - Leica EM ACE900

Leica Freeze Fracture System - Leica EM ACE900 is a high-quality sample preparation system. Perform freeze fracture, freeze etching, and electron beam coating on the sample in one instrument.
High resolution carbon/metal composite coating is carried out using an electron beam through a rotating refrigeration platform, suitable for any TEM and SEM analysis, and providing flexible projection options. By using vacuum locks for sample and tool transfer and gate valves to control each electron beam source, the instrument can always maintain a vacuum state, ensuring fast and clean working conditions.

Order Hotline:(86)-186-0049-7749

Leica Freeze Fracture System - Leica EM ACE900 Performance
 Complete freeze fracture, freeze etching, and electron beam coating on the sample
 Unlimited research potential: The freeze fracture system utilizes redesigned slicing machines, shielding, electron beams, vacuum locks, and can be connected to the Leica EM VCT500 freeze transfer system to protect samples throughout the entire freeze SEM workflow
 The built-in modern user interface eliminates any obstacles to operation
 Innovative perspectives: Research on biology, cosmetics, food, medicine, and materials, freezing and fracturing samples for TEM (replication technology) or frozen SEM (transfer through Leica EM VCT500)
 High reproducibility and proper specimen protection: automatic/manual operation, relevant parameters will be recorded, with high reproducibility and flexibility. Large refrigerated shielding walls and sample exchange compartments ensure comprehensive protection for specimens
 Convenient and intuitive user interface, easy to operate
 Connectivity: By docking with the Leica EM VCT500 vacuum freezing transfer system, the specimen can be transferred back and forth with the instrument under appropriate conditions for examination in frozen SEM
 Higher resolution images can be obtained in just a few hours
 Quick operation: The electron beam source, sample holder, and tool all have corresponding vacuum locks for quick sample processing without waiting for the vacuum state to be reached
徕卡冷冻断裂系统-EM ACE900-1
Leica Freeze Fracture System - Leica EM ACE900 Technical Parameters
system Leica EM ACE900 Technical Parameter
Electric data
 supply voltage 220V,50Hz
 current 10A
 Standby power consumption (pumps, cooling) 600W
 consumption 1KW
 liquid nitrogen
 Consumption (cold) -150℃,2L/h
 Cooling temperature -21℃
 Cryogenic storage dewar capacity 25L,35L
 Dewar pump, two rows Individual control
 Liquid nitrogen storage tank Insulation, length:90cm
 Size and Weight
system size:Width x Depth x Height(mm) weight(kg)
 host 705x710x640 135
 —With microscope 705x900x640
 —With VCT500 interface 705x710x640
 —With VCT500 vacuum transmission chamber 1450x710x643
 console 820x780x750
 LN2 Dewar flask Φ400x800 12
 LN2 pump Φ180x720
 Nitrogen pipe size: outer diameter 6mm, inner diameter 4mm