Linkenergy Metallographic Equipments Nanjing Co., Ltd.
  • Distributive Center of Metallographic Sample Preparation Consumables

    Supply Chain of Metallographic Machines, Hardness Testers and Microscopes

  • (86)-186-0049-7749

    info@linkenergy.cn

    2944149229

(86)-186-0049-7749
Leica Leica DM6 M LIBS Integrated Laser Spectroscopic Material Analysis Two in One System
  • Leica Leica DM6 M LIBS Integrated Laser Spectroscopic Material Analysis Two in One System
  • Leica Leica DM6 M LIBS Integrated Laser Spectroscopic Material Analysis Two in One System
  • Leica Leica DM6 M LIBS Integrated Laser Spectroscopic Material Analysis Two in One System
  • Leica Leica DM6 M LIBS Integrated Laser Spectroscopic Material Analysis Two in One System
Leica Leica DM6 M LIBS Integrated Laser Spectroscopic Material Analysis Two in One System

Leica Leica DM6 M LIBS Integrated Laser Spectroscopic Material Analysis Two in One System

Leica DM6 M LIBS integrated laser spectroscopy material analysis two in one system, which is a divine assistance for elemental analysis, metallographic analysis, and cleanliness analysis. In microscopic observation, as long as you press a key easily, you can switch to LIBS light path, laser excitation of the target micro area, and get the element composition results in one second, WYSIWYG. In addition, before using DM6M LIBS for analysis, there is no need for sample preparation, which can reduce material analysis time by 90%, significantly save manpower, and improve analysis efficiency.
This new product uses Laser-induced breakdown spectroscopy (LIBS). This is an atomic emission spectrum, which can be used for qualitative and quantitative analysis of Almost all elements in the solid phase, liquid phase and gas phase collective.

Order Hotline:(86)-186-0049-7749

Leica Integrated Laser Spectroscopic Material Analysis Two in One System - Leica DM6 M LIBS Performance
 The DM6 M LIBS system combines optical observation with elemental analysis
 Visual and chemical material inspection, microstructure and composition analysis, saving 90% of time compared to electron microscopy methods
 Material analysis does not require SEM sample preparation, system adjustment, or repositioning
 Reduce workflow and streamline it into one step, with a focus on results
 Multiple tools are combined to analyze the microstructure and composition of the sample, and sufficient data is obtained within one second
 Elements or materials are identified by their characteristic spectra
 Component cleanliness analysis can quickly obtain particle composition and structural data for qualitative analysis
 Microstructure evaluation, which greatly reduces the high sample preparation cost of SEM/EDS
 Typical applications in geological sciences, electronics industry, new electronic materials, coatings, and other fields
 A powerful tool for chemical analysis research, the DM6 M LIBS solution uses Laser-induced breakdown spectroscopy (LIBS) to make qualitative chemical analysis possible
 The existing DM6000 M or DM6 M microscope can be directly modified and upgraded to the DM6 M LIBS two in one system, greatly saving costs

 Leica LIBS Instrument Advantages
 High reliability of instruments
 Remote elemental analysis without sample preparation
 Repetitive laser pulses can be used at the same point to eliminate dust and weathering layers from the sample
 Can analyze multiple elements simultaneously
 Low detection limit, able to detect trace elements
 High efficiency and fast analysis ability
 Spectra for analysis can be obtained with just a few seconds of excitation irradiation
 Very short analysis time and low power consumption
 Size of small analysis points with a diameter less than 0.6mm
 Ability to identify water and/or hydrated minerals


Characteristics of Leica DM6 M LIBS compared to SEM/EDS in Leica Integrated Laser Spectroscopic Material Analysis Two in One System

Comparison project  DM6 M  LIBS SEM/EDS
colour have not have
efficiency Very high Lower
sample preparation No preparation required Need to prepare
detection limit 100PPM(0.01%) 5000PPM(0.5%)
vacuum need not need
Sample size big less
Phase identification fast difficult
layer-by-layer can cannot
operate simple Difficult
Elemental quantification qualitative semiquantitative
Sample damage micro-damage no damage
Magnification rate Lower high


Linkenergy Metallographic Product Classification